BERGSONNE

Sense.HR

Beta

heart rate, pulse oximetry, and hydration

The fully-integrated Sense.HR optical heart-rate and SpO₂ sensor combines the advanced Analog Devices MAX86174A photoplethysmography (PPG) front end with dual Vishay VEMD1060X01 silicon PIN photodiodes and four LEDs (two green, one red, one IR) for multi-wavelength reflective optical sensing. The 20-bit ADC with a 256-word FIFO provides data at configurable rates from 1 to 2048 frames per second for external processing.

Sense.HR

Technical Summary

Package
T44-10
Packaging
12mm tape and reel (drawing)
Power
1.7–2V (system)
2.7–5.5V (system)
Components
MAX86174A (PDF), VEMD1060X01 (PDF), IN-S42CTQHIR, IN-S42ATR, IN-S42ATG
Interfaces
I2CSPI

Resources & Links

Datasheet
Download PDF
JSON Tile Definition
v0.11 (Sep 25, 2026)
ECAD Libraries
Eagle|KiCad
Discussion
Discord

Configuration

I2C address
0x6B (default)0x6A (alternate)
Interface mode
I²CSPI (4-wire)

Pad Assignments

1GND2I2C.AD03I2C.EN4I2C.CLK5I2C.DAT678INTB9VLED10V+T44-10(top view)
PadTypeFunctionNote
1⏻GND
2DI2C.AD0A pull-up to 1.8 V on the tile (R1/R2) selects address 0x6B; tie to GND for 0x6A. Never drive above 2.1 V (VDD + 0.3 V absolute maximum).
DSPI.MISO
3DI2C.ENA pull-up to 1.8 V on the tile (R1/R2) selects I2C; tie to GND for SPI. Tolerates up to 6 V.
DSPI.CS6V tolerant
4DI2C.CLK6V tolerant
DSPI.CLK6V tolerant
5DI2C.DAT6V tolerant
DSPI.MOSI6V tolerant
6—
7—
8DINTBinterrupt output, open-drain, active low; needs a pull-up on the host side (tolerates up to 6 V)
9⏻VLED2.7-5.5V LED supply
10⏻V+1.8V (1.7-2.0V)

I2C

I2C
Mode
slave
Max Clock
400kHz
Addresses
0x6B(default), 0x6A
Format
7-bit address
FunctionRequiredPad(s)
I2C.CLKYes4
I2C.DATYes5

SPI

SPI
Mode
slave
Max Clock
20MHz
Address
—
Format
—
FunctionRequiredPad(s)
SPI.MISONo2
SPI.CSNo3
SPI.CLKNo4
SPI.MOSINo5

Development Product — This is an electronic development module intended for evaluation, prototyping, and integration into other designs by qualified engineers and developers. It is not a finished consumer product and has not been independently certified for FCC, CE, UL, or other regulatory compliance. The integrator of this module into a finished product is responsible for obtaining all necessary certifications. Not intended for use in life-support systems, safety-critical applications, or any application where failure could result in personal injury or property damage.